Repair drafts of an education center
We have made drafts for repair of an education center.

Repair drawings of an educational center
Room schedule
|
Description |
|
Kitchen |
|
Storage |
|
Refrigerated cell |
|
Mechanical room |
|
Game room |
|
Hvac controls room |
|
Office |
|
Mechanical room |
Asbestos removal
- Fire door asbestos containing
- Gaskets asbestos containing
- Sink gaskets asbestos containing
- Storage doors asbestos containing
- 1 sqm flue insulant asbestos containing
General notes
Contractor shall verify on site all dimensions and conditions before starting construction work. For dimensions of demolitions see new conditions. All types of interior and exterior doors and frames shall be removed and transported to an authorized public dump. All exterior aluminum grilles and windows (with roller blind and cabinet when existing) and sills shall be removed and transported to an authorized public dump all sanitaries and accessories shall be removed and transported to an authorized public dump. Only active notes are shown on each sheet.
List of works
- Iron grate to be removed
- All ceramic wainscotings shall be removed
- Wood partition to be removed
- Wood or wood/mirror wainscotings to be removed
- Gypsum board kitchen hood casing and metal structure shall be demolished
- Neral fiber panel
- Suspended ceiling to be removed
- Gypsum board suspended ceiling to be removed
- The plaster of the interior face of the perimeter walls shall be demolished
- Metal railings to be removed from exterior stairs and ramps
- All downspouts and gutters shall be removed
- Waterproofing, thermal insulation (asbestos containing), sloping bed and lashings to be removed from plat slabs to be left in place
- Concrete exterior stairs and ramps to be demolished
- Solid brick partition walls to be demolished
- Solid brick partitions with a thickness above 15cm
- Shall be demolished
- 10-15cm thick concrete slab on grade with existing floor, setting bed and subbase shall be demolished for a medium thickness of 50cm to provide new foundation with igloo system
Not used
- 26-00cm thick clay tile/concrete slab to be demolished
- Overhanging concrete slab to be partially demolished
- Reinforced concrete pad, 60cm thick, to be demolished
- Cold storage rooms with sandwich type prefabricated panel structure. Including access doors
- Reinforced concrete flat surfaces to promide for seismic joints
- Saw cut of vertical surfaces to provide for seismic joints, doors and window openings. And new columns placing
- Removal of perimeter banister with steel pillars, including gates, frames, counterframes, anchors and cutting in sections of the members
- Complete removal of the roof including tiles, small and large
- Plank and wood frame and gutters
Removal of the suspended plastered ceiling including supporting frame. Asbestos cement stack to be removed. Metal canopy to be demolished. Disassembly of exterior metal frame, including roof, perimeter glazing, doors frames, counterframes, anchors and cutting in sections of the structural members. Removal of exterior metal shed, including anchors and cuttings in sections of the bearing members. Storage building to be demolished with mechanical equipments and handwork, where necessary. Including foundations.